Product Description:
Foley Catheter (Surgitech) Size 8 Silicone Coated Pieces 1's is a high-quality indwelling catheter designed for urinary drainage in patients who require long-term catheterization. Made from medical-grade silicone, this Foley catheter provides superior comfort and durability compared to traditional latex catheters. The silicone coating ensures smooth insertion and reduces the risk of irritation and encrustation. It is available in Size 8 and is supplied as a single sterile piece, making it suitable for both hospital settings and home care.
The Foley catheter is equipped with an inflatable balloon at the tip, which can be inflated after insertion to help secure the catheter in place within the bladder, preventing it from being accidentally dislodged. The catheter is designed to provide continuous drainage of urine and is typically used for patients who have difficulty urinating due to medical conditions such as urinary retention, post-surgical recovery, or neurological disorders.
Indications:
Foley Catheter (Surgitech) Size 8 Silicone Coated is indicated for the following:
-
Urinary Retention: For patients who are unable to void urine due to conditions such as benign prostatic hyperplasia (BPH), bladder dysfunction, or spinal cord injuries.
-
Post-Surgical Use: Following surgeries in the pelvic area, urological procedures, or surgeries that require continuous monitoring or drainage of urine.
-
Long-Term Urinary Management: In cases where short-term catheterization is insufficient or when long-term urinary management is necessary, such as for patients with chronic illnesses or disabilities.
-
Acute Urinary Obstruction: Used in emergency situations where there is acute urinary retention or blockage, preventing the patient from urinating naturally.
-
Accurate Measurement of Urine Output: Useful in critical care settings, especially in ICU or postoperative care, where accurate urine output monitoring is required for assessing kidney function and fluid balance.
Dosages:
A Foley catheter like the Surgitech Size 8 Silicone Coated does not have a "dosage" as it is a medical device used for the following procedures:
-
Insertion: The catheter should be inserted into the bladder through the urethra. A sterile technique is required to prevent infection. It is generally recommended that a trained healthcare provider perform the insertion.
-
Balloon Inflation: After insertion, the balloon at the catheter's tip is inflated with sterile water to keep the catheter in place. The amount of water needed to inflate the balloon is typically indicated in the product's instructions (usually between 5-10 mL depending on the size of the catheter).
-
Urine Drainage: Once inserted, the catheter should be connected to a drainage bag, allowing urine to be continuously drained. The catheter may remain in place for several days to weeks depending on the medical need.
-
Catheter Care: Regular cleaning of the catheter and surrounding area is essential to reduce the risk of infection. Catheter should be replaced as necessary, typically every 2 to 4 weeks or when there is a buildup of encrustation or blockage.
Side Effects:
While Foley catheters like the Surgitech Size 8 Silicone Coated are generally safe when used correctly, some potential side effects include:
-
Urinary Tract Infection (UTI): The use of an indwelling catheter can increase the risk of UTIs due to the introduction of bacteria into the urinary system. Proper sterile technique during insertion and regular cleaning are essential to minimize this risk.
-
Bladder Spasms: Some patients may experience bladder spasms, which may cause discomfort or the feeling of needing to urinate despite the catheter being in place.
-
Catheter Blockage or Encrustation: Over time, minerals in urine may form deposits that can block the catheter or cause it to become encrusted, obstructing urine flow.
-
Trauma to the Urethra or Bladder: In some cases, improper insertion or prolonged use of the catheter may cause irritation, injury, or scarring to the urethra or bladder.
-
Catheter-Associated Dermatitis: Prolonged use of the catheter may lead to skin irritation or dermatitis around the insertion site or where the catheter is in contact with the skin.
-
Leakage: In some cases, the catheter may become dislodged, or the balloon may leak, leading to urinary leakage and discomfort.
Contraindications:
The Foley Catheter (Surgitech) Size 8 Silicone Coated should not be used in the following situations:
-
Severe Urethral Stricture or Obstruction: In patients with a severe narrowing (stricture) of the urethra or a bladder outlet obstruction, a catheter may not be able to pass through the urethra, or its use may exacerbate the condition.
-
Active Urethral Infection: If there is an active infection in the urethra or bladder (e.g., severe urinary tract infection (UTI)), inserting a catheter could potentially worsen the infection.
-
Hypersensitivity to Silicone or Balloon Materials: Patients with a known allergy or sensitivity to silicone or other materials used in the catheter should not use this product.
-
Severe Renal or Bladder Dysfunction: In cases of severe kidney dysfunction or bladder failure, a Foley catheter may not be appropriate, and alternative urinary diversion options should be considered.
-
Inability to Tolerate Catheterization: Patients who cannot tolerate the catheter insertion or maintenance, or those who experience significant pain or complications from the catheter, should discontinue use and consider alternative urinary management methods.
Additional Notes:
-
Sterile Technique: It is essential that the catheter is inserted using a sterile technique to prevent infection. Healthcare professionals should follow the manufacturer's guidelines and institutional protocols for insertion and care.
-
Maintenance: The catheter should be regularly checked for proper placement, and urine output should be monitored. The catheter and drainage system should be kept clean and free from obstructions.
-
Replacement: The catheter should be replaced periodically, typically every 2-4 weeks, depending on the patient's needs and the healthcare provider's recommendation.
-
Hydration: Patients with indwelling Foley catheters should be encouraged to maintain proper hydration, as this helps to prevent complications like urinary tract infections and catheter encrustation.
Conclusion:
The Foley Catheter (Surgitech) Size 8 Silicone Coated is a reliable medical device used for urinary drainage in patients with conditions that require prolonged catheterization. It is designed to reduce discomfort and the risk of infection, thanks to its silicone coating. Proper insertion, care, and maintenance are key to ensuring effective use and minimizing complications. Always follow healthcare provider recommendations and use sterile techniques to maintain the safety and efficacy of the catheter.
Share

Product Features
Highlights
Details
Lot #
Expiry Date
"For All Your Pharma And Medical Supply Needs"
-
MEDICINES
We offer large range of generics and branded tablets, capsules, topicals, suppositories, drops or suspensions, inhalers and injections.
-
SUPPLEMENTS
High quality yet very affordable vitamins and minerals, specialty supplements, herbals and botanicals, sports nutrition, and weight management.
-
MEDICAL SUPPLIES
We serve all types of medical supplies needed in clinics, laboratories, and hospitals like cottons, gauze, alcohol, swabs, gloves, bandages, lancets, glucometer, etc.
-
MEDICAL EQUIPMENT
We also serve durable and affordable medical devices and equipment needed in clinics, laboratories and hospitals.
Subscribe to our emails
Be the first to know about new collections and exclusive offers of Bambang Pharmaceutical Depot Inc.